Endo Suturing: Ligating Loop
- Main page
- Result and Statistics
-
Categories: Endo Suturing
Courses: BESTA
The task “Endoloop” is a part of FLS Course (Fundamentals of Laparoscopic Surgery).
Learning objectives
- Proper loop positioning;
- Secure the knot by running down the rod of the pusher;
- Visual-spatial orientation;
- Fulcrum effect compensation;
- Coordinated movements of both instruments;
- Ergonomic body and hands position.
Task description
Equipment: Dissector to grasper 5 mm; pusher 5 mm with round hole; Metzenbaum curved scissors; red foam organ with 3 appendages; silk or other dark braided suture 75-120 cm long.
Setup: Place the foam organ into the jumbo clip with three appendages hanging out towards you. Locate the clip onto the distal velcro strip and adjust camera so that the foam is in the middle of the field of view. Pre-tied ligating loop with Roeder knot.
Aim of the task: Place Endo-Loop on the marked appendage and cut off the thread.
Performance: Introduce dissector and pusher with the knot into the trainer. Booth assistance with the Maryland dissector (or grasper) or one-handed technique are allowed. A locking grasper may be used to enable the use of two hands to manipulate the ligating loop.Once the loop is positioned secure the knot on the mark of the foam appendage by sliding the pusher rod down. Complete the task by cutting the end of your loop material inside the trainer.
Proficiency
The task should be practiced until it can be performed in 53 seconds with up to 1mm accuracy errors; this level of performance should be achieved on 2 consecutive repetitions or for a maximum of 80 repetitions.
Start: The first instrument is visible on the screen.
Finish: Thread has been cut inside the trainer and instruments removed.
Objective Parameters
- Time limit (sec): 180
- Target time (sec): 53
- Precision: placed on mark (<1,0 mm)
- Passing score: 100
- Path: left and right instruments
- Ambidexterity, %: not relevant
- Speed: overage left and right; maximal left and right instruments
Errors
Instrument pulls too hard;
Non-ergonomic position of the trainee, leading to back or hands strain;
Rotating wheel of scissors was not used when necessary.
Penalties
Deviation of the loop from the mark more than 1 mm.
Failures
Wrong performance of the task.
The foam organ is detached from the clip.
The slit in the drain is not closed.
Copyrights (с) 2015-2018, BESTA.guru
Parameters
Time limit (sec): 180 Time target (sec): 53 Number of points: 100 Ambidexterity, %: 0 Evaluated parameters: Standard Parameters, Loop placement precision Formula: Score = 236 – t (sec) - Penalty
-
-
-
Compare with you:
X Date Attempt
Points
Time
Time application
Precision application
Ambidext.:Path, mm Av.Speed, mm/sec Max.Speed, mm/sec
Right
Left
Right
Left
Right
LeftTarget values: 100 53 - - 0 - - - - - -